38m 5-Section Concrete Boom Pump
- ACPA certified operator included
- WSIB clearance available
- Ontario owned since 1989
All the reach of a 38 metre boom in a truck that folds down like a much smaller one. Five Z fold sections open in 7.4 metres of headroom and articulate enough to thread concrete around a standing structure rather than simply over it. This is the unit Premier sends to congested driveways, treed lots and streets with overhead wiring, where the reach is ordinary but the route to the pour is not.
Other sizes in the fleet
Premier’s own description of this unit puts it better than a spec sheet can: all the reach of a 38 metre pump, with the folded overall length of a 32. That is the trade the five section Z fold buys you. The boom stacks into a shorter package on the deck, opens in 7.4 metres of headroom, and then articulates its way out to 37.5 metres up or 32.8 metres across.
What that means on site is access. A truck that folds short pulls into a driveway a longer one cannot enter. A boom that opens low deploys under service wiring and mature trees. And five joints instead of four let the operator route the concrete around a standing structure rather than needing a clear line to the pour. On an open site none of that matters and the four section is the faster, cheaper answer. On a congested one, this is the unit that gets the job done at all.
It also reaches 25.3 metres below grade, which is worth knowing on deep foundations, walkout basements and anything on a slope. Output is 160 m³/hr rod side. Every booking includes an ACPA certified operator. Premier does not rent equipment without one.
Typical applications: infill and congested lot foundations, treed properties, older streets with overhead wiring, deep excavations and walkout basements, ICF walls, slabs and footings on awkward sites.
Figures below are taken from the Putzmeister 38Z-5 manufacturer brochure, not from summary listings elsewhere on the site. Pump figures are for the 38Z-5.16H kit, which is the configuration Putzmeister lists as standard on this chassis.
📏 Reach and Boom
| Vertical reach | 37.5 m (123′) |
| Horizontal reach | 32.8 m (107’7″) |
| Reach depth | 25.3 m (83′) |
| Unfolding height | 7.4 m (24’3″) |
| Boom sections | 5, Z fold |
| Pipe diameter | 125 mm (5″) |
⚙️ Output and Pressure
| Output, rod side | 160 m³/hr (210 yd³/hr) |
| Output, piston side | 108 m³/hr (141 yd³/hr) |
| Pressure, rod side | 85 bar (1,233 psi) |
| Pressure, piston side | 130 bar (1,885 psi) |
| Strokes per minute, rod side | 31 |
| Stroke length | 2,100 mm (83″) |
🔧 Pump and Hydraulics
| Material cylinder | 230 mm (9″), hard chromed |
| Hydraulic system | Free Flow, closed loop |
| Hydraulic pressure | 350 bar (5,075 psi) |
| Maximum aggregate | 63 mm (2.5″) |
| Water tank, pedestal | 700 L (185 gal) |
| Rotation | 365 degrees |
🚛 Outriggers and Chassis
| Outrigger spread, front | 6.0 m (19’8″) |
| Outrigger spread, rear | 8.1 m (24’7″) |
| Boom section lengths | 8.7 / 6.2 / 5.6 / 6.5 / 6.5 m |
| Overall length | 12.48 m (40’11”) |
| Overall height | 3.90 m (12’9″) |
| Total weight | 25,592 kg (56,420 lbs) |
Putzmeister also offers this boom with the 38Z-5.18H LS kit, rated 182 m³/hr piston side at 85 bar. The standard delivery line system is rated to a maximum line pressure of 85 bar (1,233 psi). Truck dimensions and weights are for the Mack MRU 613 the brochure specifies and vary with chassis and options. Need the full manufacturer document for a submittal package? Download the Putzmeister brochure PDF.
- ACPA certified operator. Every Premier operator is trained and certified to American Concrete Pumping Association standards. The unit does not go out without one.
- WSIB clearance certificate. Available on request for ICI and institutional prequalification packages.
- Daily equipment inspection. Completed before the unit leaves the yard, documented, and available if your safety officer asks.
- Lines, hoses and clamps for the configuration agreed at booking, including 2″, 3″, 4″ and 5″ line options.
- Pre-pour site walkthrough on commercial and institutional jobs. On the congested sites this unit is booked for, take it up on residential work too. Setup position is the whole job here.
- Access review from photos. Send pictures of the driveway, the wires and the trees before you book and we will tell you whether this unit opens there.
- Unionized labour standards and OHSA compliance, as required on most commercial ICI sites.
Fuel, washout facilities and site access are the contractor’s responsibility unless agreed otherwise in writing at booking.
This unit exists for awkward sites, so the access questions are the important ones. Send photos rather than measurements where you can.
- Outrigger spread. 6.0 m across the front and 8.1 m at the rear, both hydraulically extended. The rear is the wider end, so the constraint is usually behind the truck. Allow roughly 8.5 m at the rear.
- Unfolding height. 7.4 m, which is the number that sells this unit. It opens under wiring and tree canopy that would stop a four section boom of the same reach. Premier will still not set up under live lines.
- Ground bearing. 25,592 kg through four pads. Fresh backfill, buried services and septic beds need review. Cribbing or pads may be required.
- Overall length and height. 12.48 m long and 3.90 m high in transport. The height matters for low garage entries, canopies and older bridge underpasses on the access route.
- Reach depth. 25.3 m below grade, so deep excavations are within range without extra line. Confirm the excavation is shored and the boom has a clear path down.
- Washout. A washout location must be nominated before the pour. Premier does not wash out to grade or to drains.
- Rail corridors. Premier runs range limiting systems, so pours adjacent to rail are possible. Flag it at booking.
If the driveway still will not take it, the 32m ZZ is the next step down on footprint, and the trailer and line pumps get there through line when nothing else will.
Is the 38m 5-section the Right Pump for Your Pour?
Specify this unit when
- Congested driveways and infill lots where the truck has to pull in past a standing house
- Treed properties and older streets with overhead wiring, where the boom has to open in 7.4 m and then go up
- Pours that need the concrete threaded around a structure rather than dropped straight onto it
- Deep excavations, where 25.3 m of reach depth puts the end hose well below grade
- Foundations, ICF walls and slabs on lots that are awkward rather than simply small
Use a different unit when
- Straightforward open sites. The 38m 4-section reaches the same distance and sets up faster, so it costs you less time
- Genuinely tight urban work. Rear spread is 8.1 m; the 32m ZZ works in half that and opens in 5.65 m
- Anything above roughly eleven storeys or beyond 33 metres of carry. That is a 43m or larger
- Enclosed or indoor pours with no boom access. Use the trailer and line pumps
- Stone, gravel or fill. That is a telebelt job
How It Compares to the Units Either Side
| Unit | Vertical | Horizontal | Unfolds in | Best for |
|---|---|---|---|---|
| 32m Alliance ZZ | 31.4 m | 26.9 m | 5.65 m | The tightest access in the fleet |
| 38m 4-section Alliance | 37.1 m | 33.1 m | 8.9 m | Open sites, quickest setup at this reach |
| 38m 5-section Putzmeister (this unit) | 37.5 m | 32.8 m | 7.4 m | Congested lots, wires and trees, deep excavations |
The two 38 metre units are within half a metre of each other on reach. Everything that separates them is in the last two columns: how low the boom opens and how much it bends.
Where the 38m 5-Section Earns Its Place
Premier runs two 38 metre booms and they go to different sites. This one goes where the problem is not distance but everything in between: a driveway with a finished house on one side and a hedge on the other, a lot with mature trees over the setup position, an older street where the service wiring crosses exactly where the boom wants to open.
Five sections and a 7.4 metre unfolding height are what make that possible. The boom opens low and then articulates its way to the placement point, which a four section boom of the same reach simply cannot do. It also reaches 25.3 metres below grade, which matters on deep foundations and walkout basements. If you are choosing between the two, the 4-section page sets out the other side of the argument, and how far a boom pump can reach and which size to rent covers the sizing. For awkward setups generally, pump setup on complex sites is the more detailed read.
Frequently Asked Questions, 38m 5-section
What is the difference between the 5-section and 4-section 38m?
Reach is effectively identical, 37.5 m against 37.1 m. The five section unfolds in 7.4 metres against 8.9, folds down shorter on the deck, and bends at one more joint. That makes it the unit for congested driveways, overhead wires and pours that need threading. On an open site the four section sets up faster and is the better value.
Can it get into a driveway with a house already standing?
That is exactly what it is for. Premier describes it as having the reach of a 38m with the folded length of a 32m, so it pulls into driveways a longer truck cannot enter, then opens in 7.4 metres of headroom. Send photos of the driveway and anything overhead and we will confirm before you book.
How far below grade can it reach?
25.3 metres of reach depth, so deep foundations, walkout basements and sloped lots are within range without adding line. The excavation needs to be shored and the boom needs a clear path down, which we will check on the walkthrough.
Is an operator included in the rental?
Yes. Every Premier unit goes out with an ACPA certified operator. Premier does not rent pumps as equipment only. The operator coordinates with your forming crew and handles setup, placement and washout.
What placement rate can I schedule against?
160 m³/hr rod side and 108 m³/hr piston side on the standard .16H pump kit. On the sites this unit is booked for, setup and access usually govern the day rather than pump output. Give us the volume and the access and we will give you a realistic figure.
Will it fit under the wires on my street?
Often, but never assume it. The boom needs 7.4 metres to unfold, and the truck is 3.90 metres high in transport, which also matters for canopies and underpasses on the way in. Premier will not set up under live lines under any circumstances. A photo taken from where the truck would stand, looking up, answers this in about a minute.
Popular Equipment
The units Ontario contractors book most often, alongside this one.

38m 4-Section
Same reach, one fewer joint. Faster to set up when the site is open and the pour is straightforward.

32m Alliance ZZ
Half the outrigger footprint and a 5.65 m unfolding height, for sites even this unit cannot get into.

Trailer and Line Pumps
For basements, indoor pours and sites with no boom access at all. Reaches through line instead of over the top.
Check Availability for the 38m 5-Section
Send a photo of the access and where the truck would stand. On congested sites that tells us more than any measurement, and we will confirm which 38m to send. No obligation.